<LOGO>
FM Transmitter Measurement Report
Created: 2026-10-22 01-28-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 4/5, 32 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 17 kHz 8033 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,7 dBr -0,39 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:27, 22.10.2026
RT
"Jak to vidi... - Karel Vyrut z Asociace cestovnich kancelari...."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 17 kHz MIN: 13 kHz % above 77 kHz: 0,0000 Acquired: 2026/10/22 1:27:58 Total samples: 8033 Equivalent time: 0:06:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,1 dBr MIN: -0,7 dBr AVE: -0,39 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2026/10/22 1:27:58) 01:14 01:16 01:18 01:20 01:22 01:24 01:26 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality